Vista de página 0
ZL105638
OPERATING &
I
NSTRUCTION
M
ANUAL
NEPTUNE SERIES 500 PUMPS
MODEL 481 THRU 547
500-A, 500-D, 500-E, 500-S and 500-VS Types
Tel.: 215-699-8700
FAX: 215-699-0370
PUMP SOLUTI ONS GROUP
DOVER
A COMPANY
NEPTUNE
MEMBER OF
TM
A COMPANY
A COMPANY
204, Dekalb Pike,
Lansdale
,
PA 19446
Vista de página 0
1 2 3 4 5 6 ... 43 44

Resumo do Conteúdo

Página 1 - NSTRUCTION

ZL105638 OPERATING & INSTRUCTION MANUAL NEPTUNE SERIES 500 PUMPS MODEL 481 THRU 547 500-A, 50

Página 2 - SAFETY INSTRUCTIONS:

7 4.0.1 (Continued) To protect the external piping system, it is recommended that a relief valve as manufactured by Neptune Chemical Pump Company, or

Página 3 - TABLE OF CONTENTS

8 4.0.3 Parts required to test or adjust Relief Valve Pressure. 1 Pc. 1/2” Pipe Nipple 6” Long 2 Pcs. 1/2” Pipe Nipple 2” Long 1 Pc. 1/2” Hand

Página 4

9 4. On initial gearbox fill or after replacing hydraulic fluid, run pump for one-half to one hour to warm up oil and allow air bubbles to dissipate.

Página 5 - RETURN GOODS AUTHORIZATION

10 SECTION III NORMAL MAINTENANCE AND DISASSEMBLY INSTRUCTIONS 9.0 MAINTENANCE Under normal conditions, the “dia-Pump”does not require any signi

Página 6 - TEL: 215-699-8700

11 FIGURE V CUT-AWAY VIEW OF VALVE SECTION, METAL HEAD PUMP FIGURE VI VALVE CARTRIDGE REMOVAL, METAL HEAD PUMPFIGURE VII VALVE CARTRIDGE REMOVAL, PVC

Página 7

12 FIGURE VIII REMOVAL OF CONTROL ROD ASSEMBLY5. Replace Control Rod “O” Ring (FIG. #517) and Sealing Plate “O” Ring (FIG. #516). 6. Take care when

Página 8 - OIL LEVEL.DWG

13 14.0 REMOVAL OF PUMP HEAD AND REPLACEMENT OF DIAPHRAGM (Continued) FIGURE IX FIGURE X 15.0 REMOVAL OF MOTOR FROM STANDARD “dia-PU

Página 9 - IN PVC HEAD PUMP

14 SECTION IV MOTOR OPERATING CONDITIONS 16.0 The Standard Series 500 “dia-Pump” is supplied with a 1/3 HP or 1/2 HP/single phase/totally enclosed

Página 10 - FIGURE IV

15 SECTION V TROUBLE SHOOTING CHART SYMPTOMS CAUSES REMEDIES 1. Pump Motor Will Not Operate. A. Blown Fuse. A. Check for short circuit or overlo

Página 11

16 SYMPTOMS CAUSES REMEDIES L. No foot valve strainer. L. Install one. *3. Pump delivers erratically. A. Leaky suction line. A. Repair or r

Página 12

WARNING LOCKOUTS ARE REQUIRED BEFORE SERVICING THIS EQUIPMENT. SAFETY INSTRUCTIONS: Shut off/Lockout pump Pow

Página 13

17 SECTION VI SEE ELECTRIC STROKE CONTROL INSTRUCTION MANUAL FOR PUMPS FURNISHED WITH OPTIONAL ELECTRIC STROKE CONTROL. SPECIAL INSTRUCTIONS FOR SE

Página 14

18 SECTION VII PARTS LIST PARTS FOR PUMP WITH METAL HEADS SERIES 500 AND 500-A PUMP PARTS FIG. NO. DESCRIPTION QTY. PART NO. 500

Página 15

19 SPARE PARTS KIT (N1 AND N3 CONSTRUCTION) MODELS 500 THROUGH 547 FIG. NO. DESCRIPTION QTY. PART NUMBER 539 Discharge Valve Cartridge 1 000209

Página 16

20 PARTS FOR PUMPS WITH MOTOR FLANGE ADAPTER, (REFER TO PARTS DRAWING 000911 ON PAGE 25) FIG. NO. DESCRIPTION QTY. PART NUMBER 507 Bearing Cup 1

Página 18 - TROUBLE SHOOTING CHART

22 SERIES 500 PVC HEAD ASSEMBLY WITH SMALL CAVITY (ASSEMBLY P/N 002074) SERIES 500 PVC HEAD A

Página 19

23 DRAWING #000911 DRAWING # FALP NEWOLD

Página 20

24 APPENDIX Addendum to Operating and Instruction Manual for the 500 dia-pump and 500-A dia-pump This sheet describes the differences in liquid h

Página 21 - SECTION VII PARTS LIST

25 CAST IRON&316SSPVC & KYNARAPPENDIX Addendum to Operating and Instruction Manual for the 500 dia-pump and 500-A dia-pump This sheet des

Página 22

26 APPENDIX THE FOLLOWING CHANGES IN TEXT MUST BE CONSIDERED WHEN USING THIS MANUAL FOR THE SERIES 500-A “dia-PUMP”. EXCEPT FOR THE DIFFERENCES

Página 23

TABLE OF CONTENTS SECTION PARAGRAPH PAGE I — GENERAL DESCRIPTION 1 LIMITED WARRANTY 2 PARTS ODERING INSTRUCTIONS 3 II — INSTALLATION

Página 24

27 Drawing 5024

Página 25 - E only. See Page 27

28 APPENDIX INTRODUCTION The Neptune Series 500 “dia-Pump” is available with a special liquid end to handle higher viscosity liquids. Model num

Página 26

29 APPENDIX INTRODUCTION A special version of the Neptune Series 500 Pump is the Model 481. This pump is different than the standard pump due to

Página 27 - SERIES 500-E-AR

30 WORM GEAR ECCENTRIC, 18 SPMP/N 003517WORM, 18 SPMP/N 003516PISTON, 5/16" DIA.P/N 003390CONTROL ROD, 5/32" DIA.P/N 003388SEALING PLATEP/N

Página 28 - PVC & KYNAR

31 APPENDIX ADDENDUM: Special instructions for Series 500, 500-A & 560 “dia-Pumps” with Double Diaphragm THEORY OF OPERATION VACUUM AIR FRO

Página 29 - SERIES 500

32 APPENDIX ADDENDUM: Special instructions for Series 500, 500-A & 560 “dia-Pumps” with Double Diaphragm 1.0.8 Close valve Item No. 5 1.0

Página 30 - Drawing 5024

MATERIAL SAFETY DATA SHEET Page 1 of 4 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Página 31 - SERIES 500-VS

2 EP 68 Gear Oil Page 2 of 4 6. ACCIDENTAL RELEASE MEASURES SPILLS OR LEAKS: Contain spills, advise EPA, st

Página 32 - MODEL 481

3 EP 68 Gear Oil Page 3 of 4 11. TOXICOLOGICAL INFORMATION – cont’d SEVERELY SOLVENT REFINED HEAVY PARAFFIN

Página 33 - MODEL 481 LOW VOLUME PUMP

4 EP 68 Gear Oil Page 4 of 4 15. REGULATORY INFORMATION TSCA: This material complies with the TOXIC SUBS

Página 34 - DOUBLE DIAPHRAGM OPTION

1 SECTION I GENERAL DESCRIPTION The Neptune Series 500 “dia-PUMP” is a reliable metering pump of the high-pressure diaphragm type. Under constant con

Página 35

5 MATERIAL SAFETY DATA SHEET Page 1 of 4 3. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Página 36

6 EP 90 Gear Oil Page 2 of 4 6. ACCIDENTAL RELEASE MEASURES SPILLS OR LEAKS: Contain spills, advise EPA,

Página 37

7 EP 90 Gear Oil Page 3 of 4 11. TOXICOLOGICAL INFORMATION – cont’d SEVERELY SOLVENT REFINED HEAVY PARAF

Página 38 - 13. DISPOSAL INFORMATION

8 EP 90 Gear Oil Page 4 of 4 15. REGULATORY INFORMATION TSCA: This material complies with the TOXIC SUBST

Página 39 - 15. REGULATORY INFORMATION

9 MAINTENANCE LOG Spare Parts Kit #____________________________________________________________ NEPTUNE CHEMICAL PUMP CO., INC. Tel.: 215-699

Página 40

2 SECTION I NEPTUNE CHEMICAL PUMP COMPANY LIMITED WARRANTY All Neptune Pumps are tested at the factory prior to shipment. Each part used in their co

Página 41

3 A COMPANYwww.neptune1.comDOVERCHEMICAL PUMP CO.LANSDALE, PA 19446TEL: 215-699-8700 PARTS ORDERING INSTRUCTIONS The complete

Página 42

4 SECTION II INSTALLATION INSTRUCTIONS 1.0 GENERAL 1.0.1 When unpacking a pump or chemical feed system, be certain that no parts are thrown away.

Página 43

5 1.0.11 Set capacity knob to zero and remove Air Bleed Plug from the top of Oil Chamber, refer to drawings HP-1102 (page 21) for Ser

Página 44 - MAINTENANCE LOG

6 FIGURE II IN METAL HEAD PUMP FIGURE III IN PVC HEAD PUMP ANTI-SIPHONSPRINGP/N 000257ANTI-SIPHONSPRINGP/N 100198P/N 1001993.0 DISCHARGE PIPING 3.0.1